To synchronize Specman Elite with a simulator, we need to define callbacks.

Start of callback: When the simulator pauses and gives control to Specman Elite.
Pauses are triggered by @sim events in e.

End of callback: When Specman Elite pauses and gives control back to the simulator.
Pauses are caused by wait/sync actions in e.


The @sim EventThe simulator will apuse and give control to Specman Elite when it sees change in a signmal in an @sim event. event clock_e is rise(â~@~X~/top/clkâ~@~Y)@sim;